Rated pressure |
34MPa |
|
P1 |
270L/min |
|
P2 |
270L/min |
|
Rated flow rate |
430L/min |
|
Hydraulic control pressure |
6~28bar When the confluence is controlled externally: in order to prevent the confluence impact, the delay is about 3S |
|
Working fluid |
Mineral oil (HL, HLP) according to DIN51 524 |
|
Fluid viscosity range |
10~380mm2/s |
|
Working oil temperature |
-20℃~+90℃,F(xiàn)or lower temperature requirements, please contact Yuzhou Technology; |
|
The max allowable pollution degree of oil |
level 9 according to NAS1638 |
|
Recommended filter filtration precision |
minimum β10≥75 |
|
? Oil port size |
T1: SAE 2 3000PSI; Ai, Bi: SAE 1 1/4 6000PSI;? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? ? P1, P2: G1 1/4; ai, bi, MP1, MP2, MLS1, MLS2, Pt: G1/4; ? |
If you have lower temperature requirements, please contact YUZHOU engineer;